- PRODUCTS
- >
- Software
- >
- Ocean Optics Software
- >
- National Instruments Ocean Optics Drivers
National Instruments Ocean Optics Drivers
SKU:
$0.00
Unavailable
per item
Ocean Optics 2000 4000
Certified LabVIEW Plug and Play (project-style) Instrument Driver
Driver SpecificationsManufacturer(s): Ocean OpticsInterface(s): USB
Driver Version: 1.4.4
Original Release Date: 12-NOV-2009
Update Release Date: 02-MAR-2016
Models Tested: USB4000
Other Supported Models: See Inset List
NI Certified? Yes
NI Supported? Yes
Certified LabVIEW Plug and Play (project-style) Instrument Driver
Driver SpecificationsManufacturer(s): Ocean OpticsInterface(s): USB
Driver Version: 1.4.4
Original Release Date: 12-NOV-2009
Update Release Date: 02-MAR-2016
Models Tested: USB4000
Other Supported Models: See Inset List
NI Certified? Yes
NI Supported? Yes
Working with the National Instruments Driver
Using the National Instruments Driver will require installing NI-Visa software and the
appropriate NI Driver.
The driver supports reasonable functionality, but does not have the built in
calculation subroutines included in Ocean Optics Omnidriver (with SPAM): mathematical
processing of spectral information will require the appropriate VI's be created.
Addressing the internal spectrometer I/O is not supported in Labview.
The NI software was tested with a USB 4000, however most Ocean spectrometers
use the same communication protocol.
Application Development Environment Minimum Software Required
LabVIEW 8.2.1 NI-VISA 5.4
LabVIEW 2012 NI-VISA 5.4
LabVIEW 2014 NI-VISA 5.4
LabVIEW 2015 NI-VISA 5.4
Note:
Versions of Labview previous to 8.2.1 will not work with the NI Ocean Optics Driver
The appropriate driver and additional information can be downloaded from: NI Instruments
Downloading the driver will require registering with National Instruments.
There is on charge for the driver
appropriate NI Driver.
The driver supports reasonable functionality, but does not have the built in
calculation subroutines included in Ocean Optics Omnidriver (with SPAM): mathematical
processing of spectral information will require the appropriate VI's be created.
Addressing the internal spectrometer I/O is not supported in Labview.
The NI software was tested with a USB 4000, however most Ocean spectrometers
use the same communication protocol.
Application Development Environment Minimum Software Required
LabVIEW 8.2.1 NI-VISA 5.4
LabVIEW 2012 NI-VISA 5.4
LabVIEW 2014 NI-VISA 5.4
LabVIEW 2015 NI-VISA 5.4
Note:
Versions of Labview previous to 8.2.1 will not work with the NI Ocean Optics Driver
The appropriate driver and additional information can be downloaded from: NI Instruments
Downloading the driver will require registering with National Instruments.
There is on charge for the driver