- PRODUCTS
- >
- Spectrometers, Detectors, Fiber Optic Cables,and Accessories
- >
- Ultraviolet to Visible Spectrometers
- >
- Ocean FX High Speed Spectrometers
Ocean FX High Speed Spectrometers
SKU:
$4,363.00
4188
5313
$4,188.00 - $5,313.00
Unavailable
per item
The newest Ocean Optics spectrometer, Ocean FX, is distinguished by features such as a high-sensitivity CMOS detector, onboard spectral buffering and Ethernet communications. But perhaps most exciting is the spectrometer’s remarkable acquisition speed – up to 3,000 scans per second, depending on the performance of its operating software and the operating system and computer to which it is connected.
DETECTOR
Detector:Hamamatsu S11639 CMOS
Spectral response range:200-1100 nm
SPECTROSCOPIC
Configurations:
UV-Vis (200-850 nm),
Vis-NIR (350-1000 nm) and extended-range
(200-1025 nm), with enhanced sensitivity versions of each also available
Optical resolution:Depends on configuration; 0.8 nm (FWHM) w/600-line/mm grating and 5 μm slit
Signal-to-noise ratio (single scan): ~270:1
Dynamic range (single scan): ~6400:1
Integration time: 10 μs-1 second
Scan rate (maximum): 3,000 scans/second (varies by performance of operating computer and system)
Buffer depth: 50,000 spectra
Thermal stability: 0.11 pixels/°C
Entrance slit: 5, 10, 50, 100 or 200 µm widths
Input fiber connector: SMA 905 or FC
ENVIRONMENTAL AND COMPLIANCE
Storage temperature:- 30 °C to +70 °C
Operating temperature: 0 °C to +50 °C
Software: OceanView, OmniDriver and SeaBreeze
Material: RoHS
Electrical: CE, FCC, CISPR 11:2010, EMC 2004/108/EC and EN61326-1:2013
For custom configurations or questions about configuration please contact us.
DETECTOR
Detector:Hamamatsu S11639 CMOS
Spectral response range:200-1100 nm
SPECTROSCOPIC
Configurations:
UV-Vis (200-850 nm),
Vis-NIR (350-1000 nm) and extended-range
(200-1025 nm), with enhanced sensitivity versions of each also available
Optical resolution:Depends on configuration; 0.8 nm (FWHM) w/600-line/mm grating and 5 μm slit
Signal-to-noise ratio (single scan): ~270:1
Dynamic range (single scan): ~6400:1
Integration time: 10 μs-1 second
Scan rate (maximum): 3,000 scans/second (varies by performance of operating computer and system)
Buffer depth: 50,000 spectra
Thermal stability: 0.11 pixels/°C
Entrance slit: 5, 10, 50, 100 or 200 µm widths
Input fiber connector: SMA 905 or FC
ENVIRONMENTAL AND COMPLIANCE
Storage temperature:- 30 °C to +70 °C
Operating temperature: 0 °C to +50 °C
Software: OceanView, OmniDriver and SeaBreeze
Material: RoHS
Electrical: CE, FCC, CISPR 11:2010, EMC 2004/108/EC and EN61326-1:2013