FEATURES
Main Unit:On board IRGA for CO2 Analysis,
H2O Analysis with humidity sensor capacitor,
Flow Control, Pump, Display and Key Board,
Leaf Chamber attachment ports and Battery.
Display: LCD 40 x 6 characters or 320 x 64 pixel
Data Storage: 4 MB Internal FLASH RAM
Data Output: USB
Flow Rate: 100 ~ 1000 cm2 / min
Operating Temperature: 0-45° C
Operating RH: 0-90% non-condensing
Power Supply: 7.2 VDC, 4400 mAh for 5 hours continuous use, extended hours of use with additional batteries.
AC Adapter / Battery Charger supplied.
Weight: 1.5 Kg (3 Lbs) with Battery
Dimensions: 44 cm x 5.5 cm x 5 cm
CO2 Analyzer
Sensor: Low power Non-Dispersive Infrared Gas Analyzer
Chopping Frequency: 1Hz
Sensors Response Time: 35 seconds
Source Life: 5,000 hours
Measuring Range: 0 to 2000 ppm (Standard) - 0 to 3000 ppm (Optional)
Resolution: 0.1ppm
Repeatability: ±0.1 ppm (short term)
Accuracy: < ± 2% up to 2000 ppm
Sample Cell: 100 mm x 10.2 mm (3.94” L x 0.40” Dia)
H2O Analyzer
Sensor Type: Humidity Sensitive Capacitor
Stability: Stable Analyzer for accurate H20 measurements
Measuring Range: 0 to 100%
Resolution: 0.1%
Accuracy: ±2% at 10% RH, ±3.5% at 95% RH
PAR Measurement
Sensor Type: Filtered GaAsP - Photodiode
Measuring Range: 0 ~ 2500 µmol m-2s-1
Accuracy: ±5 µmol 0-2500 µmol / m2 / sec
Chamber Temperature Measurement
Sensor Type: Thermocouple
Display: LCD 40x6 characters 320x64 pixel
Measuring Range: -15 ~ 50°C
Accuracy: ±0.1°C
Leaf Temperature Measurement
Sensor Type: Infrared Sensor
Measuring Range: -10 ~ 50°C
Accuracy: ±0.3˚ C
What is Included:
The CI 340 Handheld Photosynthesis System includes:
Handheld photosynthesis analyzer—display, keypad, computer, data memory, CO2 and H2O gas analyzers, flow control system, and battery.
Leaf Chamber (default LC-1)
PAR sensor
Infrared temperature sensor
Soda lime and Silica Gel tubes
Spare part kit
Rechargeable battery and charger
USB cable
Optional Control Modules:
Contact us for applications and pricing assistance
- Lightweight and optimized for single-handed operation
- Stable analyzers for accurate CO2and H2O measurements
- Accommodates open and closed system measurements
- Infrared, non-contact leaf temperature sensor
- Ten interchangeable chambers customized for different leaf types
- Custom soil respiration chamber
- Control modules for light, temperature control, CO2 / H2O supply and chlorophyll fluorescence measurement
- Chlorophyll fluorescence and photosynthesis measured simultaneously
Main Unit:On board IRGA for CO2 Analysis,
H2O Analysis with humidity sensor capacitor,
Flow Control, Pump, Display and Key Board,
Leaf Chamber attachment ports and Battery.
Display: LCD 40 x 6 characters or 320 x 64 pixel
Data Storage: 4 MB Internal FLASH RAM
Data Output: USB
Flow Rate: 100 ~ 1000 cm2 / min
Operating Temperature: 0-45° C
Operating RH: 0-90% non-condensing
Power Supply: 7.2 VDC, 4400 mAh for 5 hours continuous use, extended hours of use with additional batteries.
AC Adapter / Battery Charger supplied.
Weight: 1.5 Kg (3 Lbs) with Battery
Dimensions: 44 cm x 5.5 cm x 5 cm
CO2 Analyzer
Sensor: Low power Non-Dispersive Infrared Gas Analyzer
Chopping Frequency: 1Hz
Sensors Response Time: 35 seconds
Source Life: 5,000 hours
Measuring Range: 0 to 2000 ppm (Standard) - 0 to 3000 ppm (Optional)
Resolution: 0.1ppm
Repeatability: ±0.1 ppm (short term)
Accuracy: < ± 2% up to 2000 ppm
Sample Cell: 100 mm x 10.2 mm (3.94” L x 0.40” Dia)
H2O Analyzer
Sensor Type: Humidity Sensitive Capacitor
Stability: Stable Analyzer for accurate H20 measurements
Measuring Range: 0 to 100%
Resolution: 0.1%
Accuracy: ±2% at 10% RH, ±3.5% at 95% RH
PAR Measurement
Sensor Type: Filtered GaAsP - Photodiode
Measuring Range: 0 ~ 2500 µmol m-2s-1
Accuracy: ±5 µmol 0-2500 µmol / m2 / sec
Chamber Temperature Measurement
Sensor Type: Thermocouple
Display: LCD 40x6 characters 320x64 pixel
Measuring Range: -15 ~ 50°C
Accuracy: ±0.1°C
Leaf Temperature Measurement
Sensor Type: Infrared Sensor
Measuring Range: -10 ~ 50°C
Accuracy: ±0.3˚ C
What is Included:
The CI 340 Handheld Photosynthesis System includes:
Handheld photosynthesis analyzer—display, keypad, computer, data memory, CO2 and H2O gas analyzers, flow control system, and battery.
Leaf Chamber (default LC-1)
PAR sensor
Infrared temperature sensor
Soda lime and Silica Gel tubes
Spare part kit
Rechargeable battery and charger
USB cable
- Communication software
- Operation manual
- Instrument case
- 1st year of annual maintenance (USA only)
Optional Control Modules:
- Temperature
- CO2 and H2O
- Light
- Chlorophyll Fluorescence
Contact us for applications and pricing assistance